High‑Dk Ortho‑k for an Active Lifestyle
Orthokeratology may now be best known for myopia management, but its original purpose was to provide freedom from daytime contact lens wear. This case is a reminder that ortho-k still offers an elegant solution to many of the everyday problems associated with conventional methods of vision correction.
ITAL LENT
Design: Ortho-K Alexa AR
Material: Optimum Infinite (180 Dk)
Anterior segment observed healthy. Break up time (BUT) of 8s in both eyes.
TOPOGRAPHY OD
TOPOGRAPHY OS
The patient was deemed suitable for Orthokeratology treatment with Alexa AR design and Optimum Infinite material.
Trials were performed according to design recommendations.
A centrally positioned inter‑palpebral fluorescein pattern is observed, with appropriate movement and an ideal diameter for the fitting.
| EYE | C PW | C POT | DIA | DESIGN |
| OD | U | 02 | 10.8 | ALEXA AR |
| OS | W | 04 | 10.8 | ALEXA AR |
RECOMMENDED MATERIAL:
For this case, the Optimum Infinite material from Contamac was specifically chosen over 100 Dk options for the following critical clinical reasons:
TOPOGRAPHY POST TREATMENT OD
ANTERIOR SEGMENT OD
ANTERIOR SEGMENT OS
Topography post-treatment revealed a perfect oblate pattern with a centred treatment zone in both eyes. Corneal health remained impeccable, with no staining or anterior segment alterations, demonstrating the effectiveness of high oxygen transmissibility.
The use of Optimum Infinite turned this case into a resounding success. Not only did we achieve the desired visual correction, but we also ensured long-term ocular health.
“Being able to train at the gym without my glasses slipping or feeling dry eyes from soft contact lenses has changed my life. Now I wake up, remove my lenses, and see perfectly all day. My eyes feel fresh even after working all day in the office.”
Dr Ricardo Mojica Leal graduated as an optometrist from La Salle University (ULSA), with a diploma in Primary Eye Care. He now has more than 45 years of clinical experience in contact lenses and over thirty years dedicated to university teaching, and has been a key figure in the education of generations of optometrists and ophthalmologists in Colombia and Latin America. He has been a pioneer in the development of gas permeable contact lens designs in South America, and has led significant academic and scientific initiatives that have driven innovation and strengthened professional practice in optometry. He currently serves as Scientific Director of Ital Lent S.A.S., a leading company in the Colombian contact lens market, where he continues to promote scientific excellence, applied research, and professional development. In addition, he actively participates as a speaker at various national and international events, sharing his knowledge and experience with the optometric and ophthalmological community.